Cat.6 Shielded Patch Cord

Cat.6 Patch cords allow you to complete and optimise your Cat.6 system to EIA/TIA 568B, ISO 11801 and EN 50173-1 Class D levels of performance.  The module boot provides better mechanical protection and insures minimum bend radius is not exceeded.

Cat.6 Shielded Patch Cords are key components of the Cat.6 shielded end-to-end solution. Cat 6 Patch Cords are designed to support high speed networks. The patch cable is made from high quality four pair 26 AWG stranded copper wire. Available in a range of colors and lengths, Cat.6 patch cords are pre-terminated with RJ45 plugs and feature anti-snag slim strain relief slip on boots.

Application:

Cat.6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a cross connect or Consolidation Points for maximum system flexibility. They will also maximize the lifetime and long term performance of the system by minimizing the risk of wear & tear damage which can be caused by using non-matched cords. .Cat.6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retrofit Latch Protector, which can be used for colour coding of different services.

 

Features:

- Slim plug and boot design provide additional space between adjacent plugs

- Supports to 1Gb/s

- Individually tested up to 250MHz

- Meets or exceeds Category 6 performance standards

- 4-Pair stranded Unshielded 24 AWG conductors

- Non-plenum (CM rated)

- Universal wiring (T568A/T568B)

- Lead-Free (no heavy metals)

- Six color-coded keyed designs limit improper connections in segregated networks

- Universal wiring (T568A/T568B)

- Shielded and unshielded cable assemblies

Mechanical characteristics:

Operating Temp.Range:                                          -20°C ~ +75°C

Max.Recommended Pulling Tension:                      110N

Min. Bend Radius (install):                                       4 x O.D.

Flame Test:                                                              CMX, CM, CMG, CMR. IEC60332-1

 

Electrical characteristics:

Nom. Mutual Capacitance @ 1KHz:                         ≤5.6 nF/100m (@ 1KHz)

Max. Capacitance Unbalance (pF/100m):                ≤330 pF/100m

Nominal Velocity of Propagation:                             65%

Max. Delay Skew (ns/100m):                                   45 ns/100m

Max. Conductor DC Resistance @ 20 Deg.C:         8.76Ω/100m

Max. DC Resistance Unbalance @ 20 Deg.C:        ≤5%

Max. Insulation Resistance ( MΩ/km):                     5000

Max.Operating Voltage-UL:                                     300V 