Cat.6 UTP Cable

Tested to 250 MHz and with guaranteed performance to 250 MHz, XGOALCat.6 cables provide guaranteed headroom and bandwidth over and above the requirements of all international, european and american cable standards, including ISO/IEC 11801:2002, IEC 61156-5, EN 50173, EN 50288, TIA/EIA 568-B.2-1.

XGOAL Category 6 UTP cable is designed for optimal support of High-Speed data protocols delivering 1 Gbps performance to the workstation. Designed to be quick and easy to install the cable requires no specialist installation tools and is supplied in reelex packaging for fast, snag free installation. To reduce wastage each cable is numbered from 305metre to 1 metre, allowing quick and easy calculation of the cable remaining in the box. The inclusion of a polyethylene cross filler ensures optimum cross talk performance.

Application:

Cat.6 cable is the ultimate solution for a future proof network. It is specifically designed to support the exacting requirements for tomorrow's protocols, yet is fully backwards compatible with today's needs. It is the recommended cable for all forthcoming installations.

10baseT Ethernet

100baseTX Fast Ethernet

1000baseTX Gigabit Ethernet

155 MBit ATM

622 MBit ATM

1.2 Gbit ATM

Future class E applications

 

Features:

-Complies to all Category 6 cable standards

-Performance characterized to 250 MHz

-Meets ANSI/TIA-568-C.2Category 6 and ISO Class E 11801: 2002 specifications

-Exceeds all requirements for Gigabit Ethernet

-Central cross member maintains geometry and performance

-Lead-free (no heavy metals

-23 AWG, solid conductors

-FRPVC jacket


Mechanical characteristics:

Operating temp. range:                                 -20°C ~ +75°C

Bulk cable weight (KG):                                40 kg/km

Max. recommended pulling tension:             110 N

Min. bend radius (install):                              4 O.D.

Outer jacket tensile strength:                        ≥13.8 Mpa

Outer jacket elongation:                                ≥100%

Outer jacket aging condition:                         100 °C 168 hrs

After aging, Tensile strength:                        ≥75% of Unaging

After aging, Elongation:                                 ≥50% of Unaging

 

Electrical characteristics:

Nom. mutual capacitance:                             ≤5.6 nF/100m (@ 1KHz)

Max. capacitance unbalance:                        ≤330 pF/100m

Nominal velocity of propagation:                   65%

Max. delay skew:                                           45 ns/100m

Max. conductor DC resistance:                     73.2 Ω/km (@ 20 °C)

Max. conductor resistance unbalance:          ≤5% (@ 20 °C)

Min. insulation resistance:                             5000 MΩ·km

Max. operating voltage - UL:                         300 V

Copyright © 2022 xgoal.co.uk All rights reserved. 沪ICP备14044410号-1